Freedom 60 syringe pump manual






















Syringe of medication. FREEDOM60® IV tubing (changed every 3 days) – Tubing size: {30 ml/hr, 60 ml/hr, ml/hr} FREEDOM60 ® syringe pump. 1. Wash hands well, gather supplies, and put on gloves. 2. Verify that the medication label on the syringe has the correct patient name, medication name, expiration date, and dose. If. ANY. FREEDOM60® Syringe Pump A completely portable syringe infusion system that gives you the freedom to infuse anywhere, without the need for electricity or batteries. It operates at a constant, safe pressure, using RMS Precision Flow Rate Tubing™ to control the ‑ow rate and infusion time. 2 With syringe gradations facing up, load the syringe and its tubing into the pump. (Make sure the luer disc is fully seated in the pump’s nose.) After the infusion is complete, turn the pump o˜ and wind the large knob clockwise until the black tab is at the end of its track. Remove the empty syringe by gently pushing it back and up out of.


The Freedom 60 is a completely portable syringe infusion system that provides the freedom to infuse anywhere. It operates at a constant, safe pressure, with a wide variety of tubing sets available. It can be used for almost any subcutaneous or intravenous administration. Manufacturer: KORU Medical Systems. Condition: New. Select Syringe Driver. KORU Medical SystemsFreedom Please let us know your name. Please let us know your message. Please write a subject for your message. Please let us know your email address. Contact InfuSystem® today to learn how our pump experts can help you find the right pump. Call us toll-free *Not all items are available in Canada.


2 With syringe gradations facing up, load the syringe and its tubing into the pump. (Make sure the luer disc is fully seated in the pump’s nose.) After the infusion is complete, turn the pump o˜ and wind the large knob clockwise until the black tab is at the end of its track. Remove the empty syringe by gently pushing it back and up out of. 5. Attach the Freedom 60/Precision Tubing to the luer disc end of medication syringe. (remove clear and red caps from medication syringe). 6. Ensure the Freedom pump is in the OFF position and the black tab is at the end of its track. To. Use of any other tubing set may cause the syringe to eject from the pump and eventually cause internal damage to the pump. Page 2 BLACK TAB ON/OFF SWITCH MALE END OF FLOW RATE TUBING SYRINGE PLUNGER FREEDOM60® Product Line: Each FREEDOM60® Syringe Infusion System includes a travel pouch and user manual.

0コメント

  • 1000 / 1000